Free tool
Will this setup pass the rules?
Panels, inverter, plug and battery: check a combination against the GB plug-in rules, with the source for every limit.
- max inverter AC output by law
- 800 W
- register entries rated at the full 800 W
- 184 / 211
- compliant kits with more panel than inverter
- 15 / 28

This combination fits the rules
800 W inverter · 890 Wp of panels · 111% panel to inverter
- Inverter output 800 WWithin the 800W AC limit. Why
- 890 W of panels (DC)Within the panel limits. Why
- Output clippingAbout 10% more panel than inverter: you'll lose a little at midday in summer. Why
- No batteryFine. Why
- PlugMoulded BS 1363 plug, 5A fuse or less. Why
- ConnectionStraight into a fixed socket. Why
The whole kit must also be listed as Compliant on the ENA register: a self-assembled mix of parts usually isn’t. Check a kit.
The rules
Every limit the checker tests, and where it comes from
Plug-in solar has been legal in England, Scotland and Wales since 27 August 2026 under SI 2026/848. The detail is in the DESNZ Interim Product Specification (IPS) and the amended G98 network code.
| Part | Rule | Source |
|---|---|---|
| Inverter output | No more than 800 W AC (800 VA, 3.5 A) | SI 2026/848; IPS |
| Panels | No more than 2,000 W DC in total. Above 960 W the manufacturer must advise a wiring assessment | IPS §4.1 |
| Panel wiring | Up to 4 modules, no more than 2 in series, 120 V DC open-circuit at most, no Y-connectors | IPS |
| Plug | Moulded, non-rewireable BS 1363-1 plug with a fuse of 5 A or less | IPS; SI 2026/848 |
| Socket | A fixed BS 1363-2 socket on a socket circuit. No extension leads or adaptors | IPS; Explanatory Memorandum |
| Outdoors | Outdoor parts and outdoor sockets rated at least IP55 | IPS |
| Battery | None, built in or plug-in | SI 2026/848; IPS §1; Ofgem |
| Leakage | Device DC residual current of 5 mA or less | IPS |
| The whole kit | Listed as Compliant on the ENA Type Test Register | IPS |
| Per home | One plug-in kit per household | G98 (Ofgem) |
| With rooftop solar | Allowed if the total stays within 16 A per phase | G98 (Ofgem) |
The specification is interim. The Explanatory Memorandum says a full revision of the underlying British Standards is planned "within around 2-3 years". The rules don't yet apply in Northern Ireland: see plug-in solar in Northern Ireland.
Live data
How real kits pair panels with inverters
15 of the 28 compliant kits we track put more panel behind the inverter than it can pass on. That's allowed, and it's why the checker treats clipping as a note rather than a problem.
14
Up to 800 Wp
Panels no bigger than the inverter. No clipping.
8 in stock now
10
801 to 960 Wp
A little more panel than inverter. Clips at summer midday, gains in dull weather.
7 in stock now
4
961 to 2,000 Wp
Allowed. The manufacturer must advise you to consider a wiring assessment.
3 in stock now
Compliant kits we track with a known panel rating (28). The largest has 1,260 Wp of panels. Browse them on all kits or in stock now.
Rated output on the ENA register
| AC output | Entries | Compliant |
|---|---|---|
| 800 W | 184 | 147 |
| 799 W | 8 | 4 |
| 500 W | 10 | 9 |
| 475 W | 1 | 1 |
| 455 W | 1 | 1 |
| 440 W | 1 | 0 |
| 400 W | 4 | 3 |
| 340 W | 2 | 2 |
From the ENA plug-in register. Smaller inverters suit one-panel kits.
Common mistakes
Setups that don't pass
Each of these breaks a specific rule in the specification or G98, even when the parts work on their own.
A European kit with a plug adaptor
A Schuko plug into a travel adaptor fails twice: the plug must be a moulded BS 1363 plug, and adaptors aren't allowed. Fitting a UK plug yourself doesn't fix it either.
An extension lead to the balcony
The kit must go straight into a fixed wall socket, even an outdoor one. If there's no socket in reach, a new one is electrical work for a registered electrician.
A kit with a balcony battery
The plug-in rules don't cover batteries, whether they're built in or plug in. A battery needs an electrician to wire it in and notify your network operator.
Two kits on two circuits
The product specification would allow one per circuit, but G98 takes precedence and allows one per household until it's amended.
Panels and an inverter bought separately
A standalone inverter or a panel with a DIY plug isn't a compliant kit. Only a complete kit listed as Compliant on the ENA register is.
Five panels, or a Y-connector
The specification allows up to four modules, no more than two in series, and bans Y-connectors, even when the total stays under 2,000 W.
Sizing
Why panels can be bigger than 800 W
The legal cap is on what the inverter feeds into your wiring. Under the G98 change approved by Ofgem, a kit's registered capacity is the lower of the inverter and panel ratings, which in practice is the inverter's AC output.
Panels rarely make their full rating in the UK. Extra panel lifts output in the mornings, evenings and on cloudy days, and costs a little at summer midday when the inverter clips. The checker shows that loss as a percentage.
The limits on the panel side are 2,000 W DC, up to four modules and no more than two in series (IPS). Also check the inverter's own datasheet: each input has a maximum, and that's what the optional DC input box in the checker is for. For the trade-off in numbers, see 400 W vs 800 W.
Your home
Checking your socket and wiring
- No dedicated circuit needed. The specification covers connection "without requiring installation of a separate electrical circuit for export".
- A socket circuit only. Not a lighting circuit, and not a spur feeding fixed equipment such as a cooker or boiler.
- Modern protection. The specification says to check for RCBOs. Homes with older fuses and no RCBOs should be checked and upgraded by an electrician.
- A stronger recommendation. Electrical Safety First recommends at least a Type A bidirectional RCD. That's advice, not law.
- One kit per home. G98 allows one per household for now, confirmed in the Government Response.
More in sockets and wiring. If you're unsure what's in your consumer unit, ask a registered electrician rather than opening it yourself.
Plug-in solar compatibility: questions
Can I connect more than 800 W of solar panels to a plug-in inverter?
Yes. The 800 W limit is on the inverter's AC output. The DESNZ specification allows up to 2,000 W of panels (DC), and asks manufacturers to advise a professional wiring assessment above 960 W. 15 of the 28 compliant kits we track have more panel than inverter output.
Will a 1,000 W or 1,200 W inverter work if I limit it to 800 W?
Only if that exact kit is listed as Compliant on the ENA register. The law defines a plug-in microgenerator by a maximum rated AC output of 800 W or less, and each register entry shows the rated output. A larger inverter you've set up yourself isn't a registered kit.
Can I use an extension lead with plug-in solar?
No. The kit must plug straight into a fixed BS 1363-2 wall socket. Extension leads, multi-way adaptors, travel adaptors and plug-in RCD adaptors are all ruled out by the DESNZ specification.
Can I add a battery to my plug-in solar kit?
Not as a plug-in. The law's definition of a plug-in microgenerator excludes devices that store energy from your home's wiring for later, and the specification excludes battery systems. You can still have a battery, but it needs an electrician to wire it in and notify your network operator.
Do I need a special socket or circuit?
No dedicated circuit is needed. The socket must be a fixed socket on a socket circuit, not a lighting circuit or a spur feeding fixed equipment, and IP55 if it's outdoors. The specification says to check you have modern residual current protection (RCBO); homes with older fuses should be checked by an electrician.
Can I add plug-in solar if I already have solar panels on the roof?
Yes, if the combined output stays within 16 A per phase, according to the G98 change Ofgem approved. Above that the larger G99 process applies. Ask the installer of your rooftop system or a registered electrician if you're not sure.
Sources
- SI 2026/848: definition of plug-in microgenerator
- Explanatory Memorandum to SI 2026/848
- DESNZ Plug-in Solar Device Interim Product Specification, v2.0 (July 2026)
- Ofgem decision approving DCRP/MP/26/02 (G98 Issue 2 Amendment 1), 11 Aug 2026
- DESNZ Government Response, July 2026
- ENA Connect Direct Type Test Register (Plug-in Solar)
- Electrical Safety First: plug-in solar panels
Free tools
Plan the rest of your setup
- Compliance checkerIs this kit on the ENA register?
- Cable checkExtension leads, adaptors and your kit’s cable
- DNO finderYour network operator, by postcode or MPAN
- Real-world yieldsWhat owners’ kits actually make
- Report your yieldShare what your kit really makes
- CalculatorOutput, savings and payback for your home